Infortrend SentinelRAID 170 User Manual

Browse online or download User Manual for Memory modules Infortrend SentinelRAID 170. Infortrend SentinelRAID 170 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
SentinelRAID 170
320MB/sec SCSI-to-SCSI RAID Controller
Installation and Hardware
Reference Manual
Version 1.1 (04, 2004)
Printed in Taiwan
Page view 0
1 2 3 4 5 6 ... 79 80

Summary of Contents

Page 1 - Reference Manual

SentinelRAID 170320MB/sec SCSI-to-SCSI RAID ControllerInstallation and HardwareReference ManualVersion 1.1 (04, 2004)Printed in Taiwan

Page 2 - Contact Information

Software and Firmware UpdatesPlease contact your system vendor or visit Infortrend’s FTP site (ftp.infortrend.com.tw)for the latest software or firmwa

Page 3 - Copyright 2004

Chapter 1: IntroductionProduct Overview 1-1Chapter 1Introduction1.1. Product Overview1.1.1 Product IntroductionThis hardware manual briefly introduces

Page 4 - Warnings and Certifications

SentinelRAID 170 Installation and Hardware Reference Manual 1-2 Product Overviewconnects to a PC hyper-terminal that is used to configure the controll

Page 5 - Table of Contents

Chapter 1: IntroductionSR Components 1-3Figure 1-2: SR Enclosure Canister Mounting Holes1.2. SR Components1.2.1 LCD PanelFigure 1-3: LCD PanelThe LCD

Page 6

SentinelRAID 170 Installation and Hardware Reference Manual 1-4 SR Componentsupgrade sockets allow for the installation of a daughter board that facil

Page 7

Chapter 1: IntroductionSR Components 1-5Figure1-4: Controller Board (Front)1.2.3 InterfacesThe external interfaces (see Figure1-5) are all located at

Page 8 - About This Manual

SentinelRAID 170 Installation and Hardware Reference Manual 1-6 SR ComponentsConnector Type Label DescriptionSCSI-320 Connectors CH0, CH1, CH2 and CH3

Page 9 - Conventions

Chapter 1: IntroductionSR Accessory Items 1-71.3. SR Accessory ItemsThe following items are not installed on the controller but come in the accessory

Page 10 - Software and Firmware Updates

SentinelRAID 170 Installation and Hardware Reference Manual 1-8 Optional Items1.4.2 SCSI CablesSCSI cables are required to connect the 68-pin connecto

Page 11 - Introduction

Chapter 1: IntroductionEnvironmental Requirements 1-9Figure 1-6: IFT-9010D BBU ModuleFigure 1-7: IFT-9070D Battery Charger Board1.5.2 Daughter Board

Page 12 - 1.1.2.2 Front Side

Contact InformationAsia Pacific(International Headquarters)Infortrend Technology, Inc.8F, No. 102 Chung-Shan Rd., Sec. 3Chung-Ho City, Taipei Hsien, T

Page 13 - 1.2. SR Components

SentinelRAID 170 Installation and Hardware Reference Manual 1-10 SR Controller Monitoring1.6.2 Cooling RequirementsProper SR controller cooling is req

Page 14

Chapter 1: IntroductionSR Controller Monitoring 1-111.7.4 Audible AlarmsThe SR controllers come with audible alarms that will be triggered when certai

Page 15 - 1.2.3 Interfaces

SentinelRAID 170 Installation and Hardware Reference Manual 1-12 SR Controller MonitoringThis page is intentionallyleft blank.

Page 16 - 1-6 SR Components

Chapter 2: InstallationInstallation Overview 2-1Chapter 2Installation2.1. Installation OverviewCAUTION:Please note that the installation instructions

Page 17 - 1.3. SR Accessory Items

SentinelRAID 170 Installation and Hardware Reference Manual2-2 Hardware Installation Preparation♦ Working surface: Provide a soft, clean surface on

Page 18 - 1.5. Optional Items

Chapter 2: InstallationUnpacking the Controller 2-32.4.3 General Installation ProcedureIf the steps listed below are followed, the installation of th

Page 19 -  Power-up: 4A

SentinelRAID 170 Installation and Hardware Reference Manual2-4 Accessing the Controller Board2.6. Accessing the Controller Board2.6.1 OverviewWARNIN

Page 20 - 1.7.2 LED Indicators

Chapter 2: InstallationMemory Module Installation 2-52.7. Memory Module InstallationThe SR controller comes without a DIMM memory module. It is there

Page 21 - 1.7.4 Audible Alarms

SentinelRAID 170 Installation and Hardware Reference Manual2-6 Battery Backup Unit (BBU) InstallationFigure 2-2: Install the DIMM ModuleStep 3. Repl

Page 22 - This page is intentionally

Chapter 2: InstallationBattery Backup Unit (BBU) Installation 2-7♦ During normal use, an empty cell pack takes about 20 hours to recharge.♦ Disconne

Page 23 - Installation

Copyright 2004This Edition First Published 2004All rights reserved. This publication may not be reproduced, transmitted, transcribed,stored in a retr

Page 24

SentinelRAID 170 Installation and Hardware Reference Manual2-8 Battery Backup Unit (BBU) InstallationFigure 2-4: Install the Battery Charger BoardSte

Page 25

Chapter 2: InstallationDaughter Board Installation 2-9Figure 2-6: Connect the BBU to the Connector at the Back of the Controller BoardStep 5. Replace

Page 26 - 2.6.1 Overview

SentinelRAID 170 Installation and Hardware Reference Manual2-10 Daughter Board InstallationFigure 2-7: Install the Daughter BoardStep 3. Insert the

Page 27 - 2.7.1 Selecting the DIMMs

Chapter 3: Controller MonitoringController Monitoring Overview 3-1Chapter 3Controller Monitoring3.1. Controller Monitoring OverviewThe SR controller

Page 28

SentinelRAID 170 Installation and Hardware Reference Manual3-2 Status-indicating LEDsController monitoring is a necessary part of controller manageme

Page 29

Chapter 3: Controller MonitoringAudible Alarm 3-33.3. Audible AlarmDifferent controller environmental and operational parameters (i.e., temperature, e

Page 30

SentinelRAID 170 Installation and Hardware Reference Manual3-4 I2C Port (Enclosure Monitoring)This page is intentionallyleft blank.

Page 31

Chapter 4: Controller Connections and OperationSentinelRAID Connection 4-1Chapter 4Controller Connections andOperation4.1. SentinelRAID Connection4.1.

Page 32

SentinelRAID 170 Installation and Hardware Reference Manual4-2 SR 170 Topologies4.1.4 Drive ConnectionEach drive channel can be connected to up to fi

Page 33 - Controller Monitoring

Chapter 4: Controller Connections and OperationSR 170 Topologies 4-3Figure 4-1: Single Host Connection

Page 34 - 3.2. Status-indicating LEDs

Warnings and CertificationsFCC (applies in the U.S. and Canada)This device complies with Part 15 of FCC Rules. Operation of this device is subject to

Page 35 - C Port (Enclosure Monitoring)

SentinelRAID 170 Installation and Hardware Reference Manual4-4 SR 170 Topologies4.2.2 Dual Host ConnectionIn Figure 4-2 two channels (CH0 and CH1) a

Page 36

Chapter 4: Controller Connections and OperationController Integration 4-54.2.3 ExpansionThe installation of an optional daughter board can expand the

Page 37 - Operation

SentinelRAID 170 Installation and Hardware Reference Manual4-6 Other ConnectionsNOTE:It is recommended to use the embedded terminators on host or dri

Page 38 - 4.2. SR 170 Topologies

Chapter 4: Controller Connections and OperationPower On 4-7(Red stripe)1 2 3 4 5 6 7 8 9IFT-9512 cableDual COM Port 1 2 3

Page 39 - SR 170 Topologies 4-3

SentinelRAID 170 Installation and Hardware Reference Manual4-8 Power On Ambient temperature: All the controller components have been acclimated tot

Page 40 - 4.2.2 Dual Host Connection

Chapter 4: Controller Connections and OperationPower Off Procedure 4-9This screen appears after the initialization process. Itclearly shows the model

Page 41 - 4.3. Controller Integration

SentinelRAID 170 Installation and Hardware Reference Manual4-10 Power Off ProcedureThis page is intentionallyleft blank.

Page 42 - 4.4. Other Connections

Chapter 5: Controller MaintenanceController Maintenance Overview 5-1Chapter 5Controller Maintenance5.1. Controller Maintenance Overview5.1.1 About C

Page 43 - 4.5. Power On

SentinelRAID Installation and Hardware Reference Manual5-2 Replacing a failed DIMM Module♦ When replacing any of the controller components, it is ne

Page 44 - 4.5.3 LCD Screen

Chapter 5: Controller MaintenanceReplacing a failed DIMM Module 5-3Step 4. Remove the optional BBU charger board. The BBU charger board obstructsthe D

Page 45 - 4.6. Power Off Procedure

Table of ContentsCHAPTER 1: INTRODUCTION... 1

Page 46

SentinelRAID Installation and Hardware Reference Manual5-4 Replacing a Failed Optional BBU ModuleStep 7. Reinstall the optional BBU charger board. On

Page 47 - Controller Maintenance

Chapter 5: Controller MaintenanceReplacing a Failed Optional BBU Module 5-5Figure 5-3: Disconnect the BBU Connector from the Connector at the Back of

Page 48 - ♦ Case 1: DIMM module fails

SentinelRAID Installation and Hardware Reference Manual5-6 Daughter Board MaintenanceStep 4. Replace the chassis top cover. Once the new BBU battery

Page 49

Chapter 5: Controller MaintenanceDaughter Board Maintenance 5-7the chassis. The complete removal procedure is described in Chapter 2,Section 2.6.2.St

Page 50 - Board Backplane Connector

SentinelRAID Installation and Hardware Reference Manual5-8 Daughter Board MaintenanceThis page is intentionallyleft blank.

Page 51

Appendix A: SentinelRAID FeaturesOverview A-1Appendix ASentinelRAID FeaturesA.1. OverviewThe SR controller comes with many different features. Some of

Page 52

SentinelRAID 170 Installation and Hardware Reference ManualFault Tolerance A-2A.2.5 Controller ArchitectureThe controller is developed from Infortrend

Page 53

Appendix A: SentinelRAID FeaturesFunctional Features A-3A.4. Functional FeaturesA.4.1 RAID Levels SupportedThe following RAID levels are supported: R

Page 54

SentinelRAID 170 Installation and Hardware Reference ManualFunctional Features A-4This page is intentionallyleft blank.

Page 55 - SentinelRAID Features

Appendix B: Hardware SpecificationsConfiguration B-1Appendix BHardware SpecificationsB.1. ConfigurationSpecification FeatureRAID Levels 0, 1(0+1), 3,

Page 56 - A.3. Fault Tolerance

CHAPTER 3: CONTROLLER MONITORING ...3-13.1. CONTROLLER MONITORING OVER

Page 57 - A.4. Functional Features

SentinelRAID 170 Installation and Hardware Reference Manual B-2 Controller ArchitectureB.2. Controller ArchitectureSpecification FeatureCPUPowerPC® 7

Page 58

Appendix B: Hardware SpecificationsFault Tolerance B-3B.4. Fault ToleranceSpecification FeatureDrive S.M.A.R.T. Support Yes (with user-configurable de

Page 59 - Hardware Specifications

SentinelRAID 170 Installation and Hardware Reference Manual B-4 SoftwareB.5. SoftwareSpecification FeatureIn-band Text RAIDManagerYes (all major plat

Page 60 - B.3. RAID Management

Appendix B: Hardware SpecificationsTechnical Specifications B-5B.6.3 Controller SpecificationsDescription SpecificationCache memory At least 128MB, up

Page 61 - B.4. Fault Tolerance

SentinelRAID 170 Installation and Hardware Reference Manual B-6 Technical SpecificationsThis page is intentionallyleft blank.

Page 62 - B.6. Technical Specifications

Appendix C: Hardware TroubleshootingProblem C-1Appendix CHardware TroubleshootingC.1. Problem♦ LCD is off1. Check the power connection on the contro

Page 63

SentinelRAID 170 Installation and Hardware Reference ManualC-2 ProblemParity error detected SDRAM DIMM should be replaced.Logical drive failure detec

Page 64

Appendix C: Hardware TroubleshootingProblem C-3All settings are too complex toremember.1. After system installation is complete, write down allthe se

Page 65 - Hardware Troubleshooting

SentinelRAID 170 Installation and Hardware Reference ManualC-4 ProblemThis page is intentionallyleft blank.

Page 66

Appendix D: Spare Parts and AccessoriesSpare Parts D-1Appendix DSpare Parts and AccessoriesD.1. Spare PartsThe following table lists the available spa

Page 67

A.4.1 RAID Levels Supported ...A-3A.4.2 Controller

Page 68

SentinelRAID 170 Installation and Hardware Reference ManualD-2 AccessoriesThis page is intentionallyleft blank.

Page 69 - Spare Parts and Accessories

Appendix E: Connectors and Jumper IdentificationController Main Board Interfaces E-1Appendix EConnectors and Jumper IdentificationE.1. Controller Main

Page 70

SentinelRAID 170 Installation and Hardware Reference ManualE-2 Controller Main Board Interface DescriptionsE.2. Controller Main Board Interface Descri

Page 71 - Appendix E

Appendix E: Connectors and Jumper IdentificationLED Jumper Pin Outs E-3E.3. LED Jumper Pin OutsE.3.1 JP 2 LEDPin Description Pin Description1 Partner

Page 72

SentinelRAID 170 Installation and Hardware Reference ManualE-4 J3 I2C PortE.4.2 JP 17 RS-232C PortPin Description Pin Description1 DCD2 6 DSR22 RXD2 7

Page 73 - E.4. COM Port Pin Outs

Appendix E: Connectors and Jumper IdentificationJ1 Battery Connector E-5E.6. J1 Battery ConnectorPin Pin Name1 VB (battery voltage +)2 BAT-THM (batter

Page 74 - E.5. J3 I

SentinelRAID 170 Installation and Hardware Reference ManualE-6 IFT- 9011 Null ModemE.8. IFT- 9011 Null ModemSwap pin-2 and pin-3Swap pin-4 and pin-6Sw

Page 75 - E.7. TTL Device Parameters

INDEXIndex I--1--A--accessory box, 1-7audible alarm, 1-11, 3-1, 3-3automatic bad block assignment, A-2--B--background rebuilding, A-2base channels, 1-

Page 76 - E.8. IFT- 9011 Null Modem

SentinelRAID 170 Installation and Hardware Reference ManualI--2 IndexI/O port cabling, 2-2I2C bus, 1-10I2C connector, 1-2, 1-5, 3-3I2C, 3-1impedance,

Page 77 - Index I--1

IndexIndex I--3storage devices, 1-2surface temperature, 2-6--T--temperature threshold, 3-1terminal emulation program, 1-10, 4-6terminator, 4-5top cove

Page 78 - -2 Index

Safety PrecautionsPrecautions and Instructions• Prior to powering on the controller, ensure that the correct power range is beingused.• Ensure there

Page 79 - Index I--3

SentinelRAID 170 Installation and Hardware Reference ManualI--4 IndexThis page is intentionallyleft blank.

Page 80

Who should read this manual?This manual assumes that its readers are experienced with computer hardware installationand are familiar with RAID control

Comments to this Manuals

No comments